9-52 Parameters ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
C018 SSI Encoder Homing
00.00.0 00.00.0 76
76 = Set Absolute Encoder
The command is executed after exiting
Parameter Mode.
Reserved :
Reserved :
Set Absolute Position: If 76 is entered in this parameter, the absolute
value is set to the value stored in Reference distance, Parameter C019,
upon exiting Parameter Mode. After that, the 76 is cleared. If a parameter
error occurs, the 76 is cleared automatically, and the function must be
reprogrammed.
C019 SSI Encoder Reference Distance