15.7 Faults and Messages
Display
Position of the Displays
Display of general status messages and input/output status messages is
integrated on the electronic module. The following figure shows the
electronic module and the position of all its displays.
ek5043F1_AE.WMF
Fig. 15-21: Position of the Electronic Module Displays
General Status Displays
LED Color Status Definition Error-Clearing
H1 green on input/output module is synchronous to master
drive, synchronous data exchange with the
assigned drive
H1 orange on input/output module is synchronous to master
drive, no data exchange with the assigned drive
H1 - off input/output module is asynchronous to master
drive, asynchronous data exchange with the
assigned drive
H1 red on no communication with a drive check if...
...the bus cable is correctly connected.
the address switches on the
input/output module are correctly set.
the assigned drive controller is
turned on.
the parameters for the input/output
module assigned to the drive controller
are set correctly.