ECODRIVE03-FL*-04VRS Parameters 9-49
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
C013 Distance-Coded Reference Offsets
1001 1000
Distance-Coded Reference Offset 2
the smaller distance between 2 reference markers
Distance-Coded Reference Offset 1
the larger distance between 2 reference marks
This parameter is used for inputting the encoder-specific distances
between two reference marks for measuring systems with distance-coded
reference marks.
See also functional description for: "Homing"
C014 Encoder Emulation Configuration
0 0 0
Select Emulation
0 = no output
1 = incremental encoder emulation
2 = absolute encoder emulation
Dead-Time Compensation
0 = is deactivated
1 = is activated
Select Actual Position Source
0 = position output of motor encoder
1 = position output of optional encoder
2 = output of position command value
Select between incremental/absolute encoder emulation.
Select the source of the signal to emulate.
Note: If an second optional encoder with an SSI interface is to be
connected to Connector X9, the encoder emulation in this
parameter must be disabled.
See also functional description for: "Encoder Emulation."