ECODRIVE03-FL*-04VRS Parameters 9-31
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
9.4 General Parameters
B000 Display
1 0 00 0
reserved
reserved
Write Protection: 9 = for NC and Logic Task
Language 0 = German
1 = English
2 = French
Language
All texts are output in the selected language. The language selection
becomes active immediately after saving these parameters.
Write Protection
NC Program and Logic Task are no longer programmable.
If a write command is sent via the serial interface anyway, Status
Message 01 is issued: "26- Write Protected"
B001 Serial Interface Parameter 1
09600 1 05
Station number
00 = the set address (S3/S2) of the module
is valid.
xx = 1 32 fixed station number
Parity Check
1 = none
2 = even
3 = odd
Baud Rate: 02400 Baud
04800 Baud
09600 Baud
19200 Baud
For further details, see Section 10.2, `Serial Interface´