EasyManua.ls Logo

Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS - Data Display

Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14-20 Display ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Data Display
Display Variable
The contents of the programmed variable are written to the display
cyclically.
The contents of all variables can be displayed.
The number of places before and after the decimal can be designated.
N0500 TXT 0 1-0-2-00-100-183
Display of the Actual Position with Places Before the Decimal
Parameter Description min. max.
1 Assignment: Displays -- --
0 0 = Display Variable -- --
2 Display Line 1 6(7)
00 Display Position 00 21
100 Variable Number 000 999
-- --
0 = Without operational sign
1 = With operational sign
01
Number of Places Before Decimal 1 8
183
1xx
x8x
xx3
Number of Places After Decimal 0 6
Fig. 14-8: Variable Display
Display: Actual Position
TXT 0 1-0-3-08-100-183
V100 = Actual Value, Axis1
Display Markers
N0500 TXT 0 1-1-2-00-M2.00.0
Parameter Description min. max.
1 Assignment: Displays -- --
1 Display Marker Bit -- --
2 Line 1 6(7)
00 Position 00 21
M2.02.0 Complete Identifier
M = Marker
I = Input
Q = Output
000 999
Fig. 14-9: Marker Display

Table of Contents

Related product manuals