EasyManua.ls Logo

Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS - A110 Bipolar Jerk Limiting Time Constant

Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-10 Parameters ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
A110 Bipolar Jerk Limiting Time Constant
0.000
Time Constant for acceleration [s]
Min. = 0 (no jerk)
Max. = 1.024 s
The time constant is processed only in 2
n
values
Jerk1_AE.WMF
Fig. 9-4: Jerk
Parameter A110 can be written in all operating modes.
CAUTION
Bei nicht stehender Achse kann es bei
Änderung dieses Parameters zu ruckartigen
Bewegungen kommen.
Value should be changed preferably in standstill.