ECODRIVE03-FL*-04VRS EMD Module (EcoX-Bus) 15-3
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
15.2 Technical Data
EcoX Bus System Data
max. number of drive controllers 1
max. number of input/output modules 2
bus conductor Rexroth cable assembly
Type IKB 0036
maximum conductor length 2 m
bus connection 9-pole D-SUB connector
transmission rate 1 MBaud
Fig. 15-4: EcoX Bus Data
Input/Output Module Data
Designation Symbol Unit Value / Description
Supply
Supply Voltage U
DC
V [DC]
24 (± 20 %)
Current Consumption (Module without Load at
U
DC
=24 V)
IA
0.1 (± 20 %)
Rated Current at 24 V / 0 V I
B
A8
Total Power Loss P
V
W< 4.5
Protection for sensor power supply F1 TR5 250 V / 6.3 A T
Inputs
Number 16
Connections dual- or triple-conductor, depending
on whether the sensor requires
power supply
Signal Voltage (low or 0) U
E0
V [DC] 0 ... 5
Signal Voltage (high or 1) U
E1
V [DC] 11 ... 30
Time Constant (no bus) ms < 0.5
Electronic Isolation – Circuit Side no