8-18 Functions ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Override via Binary-Code Inputs
The evaluation is handled via inputs I0.00.6 through I0.01.4. This function
is activated in parameter AA04 or using the VEO program command.
Input Number : I0.01.4 I0.00.6
binary value : 2
6
2
5
2
4
2
3
2
2
2
1
2
0
decimal value : 64 32 16 8 4 2 1
The decimal values of all of the above inputs set to 1 are added together.
The resulting velocity is obtained as follows:
127
valuedecimalallofSum
VpVo ×=
L: Vo = Velocity
Vp = Traversing Velocity
Fig. 8-16: Velocity Calculation