ECODRIVE03-FL*-04VRS Parameters 9-25
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
AA12 Press: Signal Offset
M2.02.2 M2.02.3 00
00 = Press off for feed angle falling edge
01 = Press off for feed angle rising edge
Output Bit: Press (Continuous Operation)
M2, M3, M4
EMD : Q3.00.0-Q3.03.7
DKC21.3 : Q0.00.4-Q0.01.3
DKC 3.3 : Q2.02.0-Q2.05.7
Input Bit : Press: 0 = off
1 = on
00.00.0 = Function Off
Parameter Function AA13 Off
M0 – M5 ; M8 ; I0 – I4 ; Q0 – Q3
This parameter allows the definition of the output used to control the
press and when this output is cleared.
The press marker must be turned off in the program when the feed angle
edge is falling. Via this parameter, it is possible to offset the shutoff signal
of the feed angle rising edge. The signal to turn on the press is always
immediate.
This parameter must also be programmed when the function in
Parameter AA13 is used.
If an E-Stop, Fault, Immediate Stop, Interruption (parameter A116), switch
to Parameter Mode, or switch to Manual Mode occurs, the programmed
press output is immediately cleared.
Pr_Out_AE.WMF
Fig. 9-10: Signal Sequence for the Press