ECODRIVE03-FL*-04VRS Parameters 9-47
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
C007 Feed Constant 2
0500.0000
Feed Constant in IU
Encoder 2 is used as an optional encoder, measuring wheel axis or
master axis.
This parameter is read out only with rotary encoders.
This parameter describes the conversion from rotary to linear motion. It is
defined as the linear displacement of the load during one revolution of the
measuring wheel encoder shaft.
Input min.: 0.1000 IU
Input max.: 5000.0000 IU
C008 Reserved
C009 Homing Configuration
1 0 0 10 20
Homing Acceleration in % of amax (A108)
Homing Velocity in % of Vmax (A106)
Reference Mark Measurement:
0 = yes
1 = no
Home Switch, Evaluate:
0 = yes
1 = no
Homing Direction
0 = positive
1 = negative