9-14 Parameters ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
A116 Feed Angle Monitoring
M2.02.1 M2.02.2 0
Mode in Manual Mode:
0 = Feed Angle Monitoring active
1 = Feed Angle Monitoring inactive
Input Bit : Interruption
M0 M5 ; M8 ; I0 I4 ; Q0 Q3
Input Bit : Feed Angle Monitoring
M0 M5 ; M8 ; I0 I4 ; Q0 Q3
Feed Angle Monitoring (Feed Angle):
Whether or not the feed is to be monitored is entered at this point. If
00.00.0 is entered, there is no monitoring.
If no signal is present at the specified input bit, no feed takes place. Then
all of the NC instructions which do not contain feed distances are
executed. As soon as the NC encounters an instruction containing a feed
distance, it stops at this instruction until a signal is applied at the input bit.
If the signal drops out during feed, feed is aborted and the error message
"F-02 10 Feed Angle Loss" is generated.
Interruption:
Enter whether or not a positioning function in progress can be interrupted.
Entering 00.00.0 means there is no interrupt.
If the signal at the specified input bit is lost, any initiated positioning
functions are not executed, or those already in progress are stopped. All
instructions containing no feed distances continue to be processed as
usual.
As soon as an instruction containing a feed distance is invoked, the
program waits to process the instruction until a signal is present at the
input bit.
If the other operating conditions have been retained, execution or
continuation of the positioning function takes place as soon as the signal
is present.
Mode in Manual Mode:
Deactivate Feed Angle Monitoring in Manual Mode
This value can also be edited outside of Parameter Mode, via the serial
port.