ECODRIVE03-FL*-04VRS General Instructions for Start-Up 4-13
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Firmware Update in BTV04/05
Serial transmission to X3 takes place via the RS 232 port.
The communications parameters of the DOLFI program must be set as
follows:
Options Å Com-Port Connect baud rate 9600
Download baud rate 38400
Options Å Address Receiver 03
Caution: The BTV04*-DOL-01Vxx module must never be overwritten.
Setup Menu in the BTV
Enter the Setup Menu by
pressing the F2 key while the BTV is in the initialization phase.
OR by pressing Shift + F6
Enter the Setup Menu for Port 2 by pressing F1 (Serial Port Parameter)
and then F3 (Serial Port 2)
Set to
Address: 3
Baud Rate: 9600
Parity: off
Protocol: ASCII +SIS
Answer Delay: 1 ... 4
Timeout (ms): 400
Retry: 2
Group No.: 0
Max Unit: 0
Once these data are set, exit this input level by pressing ESC. These data
are saved by pressing F3 (Save Values and Reboot).