10-18 Interface ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
ASCII Protocol
The first control character indicates the beginning of a data transmission:
1)
? Hexadecimal 3F / character for data query
If the control receives a ?, requested information (Program Instruction,
Parameter, Status Message, Variable, Logic Task, Cam) is output.
2)
# Hexadecimal 23 / character for transmission of data
If the control receives a #, the following characters are saved into the
control (NC, Parameters, Logic Task, Variables, Cam).
3)
! Hexadecimal 21
If the control receives a !, the following characters are picked up as the
control command.
4)
: Hexadecimal 3A
Colon for polling query.
s This character identifies the station number. The s is to
be replaced by an appropriate character, depending on the operating
mode.
1) In RS232C operating mode, the s is replaced by a blank space.
However, the responses always contain the station number.
2) In RS485 mode, the s is replaced by the respective station number
(1 - 9 ; A...W for No. 10 to 32). If this number does not correspond to
the number set in the programming module, there is no response to
the received data.
If s is a blank space, this information is relevant for all users on the
bus.
The third character identifies the information type:
1)
N Hexadecimal 4E / character for NC instruction.
The information following the N is interpreted as an NC program
instruction.
2)
K Hexadecimal 4B / character for parameter.
The information following the K is interpreted as a parameter.
3)
X Hexadecimal 58 / character for status.
4)
P Hexadecimal 50 / character for Logic Task.
The information following the P is interpreted as a Logic Task instruction.
5)
V Hexadecimal 56 / character for variable.
The information following the V is interpreted as a variable.
6)
C Hexadecimal 43 / character for a command.
The information following the C is interpreted as a command.
First Control Character in the
Data String:
Second Control Character in the
Data String:
Third Control Character: