ECODRIVE03-FL*-04VRS Diagnostic Message Descriptions 12-57
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
F- 0302 NC instruction number illegal
The destination instruction number indicated in an NC instruction does not
fall within the programmed range (instruction 0 to 999).
Cause:
For constants: Data loss.
For variables: Value of the destination variable is too large or
negative. Possibly caused by access to an
incorrect destination variable when using indexed
variables.
The formula for calculating the destination variable is not fulfilled in
the BIO command.
Remedy:
Re-save the command with valid values. Check the contents of the
variable.
F- 0304 NC command illegal
Invalid NC command, or command not supported by this firmware was
processed in the program or manual vector.
Cause:
Data loss.
Remedy:
Check program.
F- 0305 not homed
Calling the commands POA, PFA, PSA, SAC, or VCC is not allowed,
because the axis is not homed.
F- 0307 Data loss parameter
The checksums via the parameters are invalid.
Cause:
Data loss.
Firmware update was executed. Previously, a different firmware or a
different version was loaded.
Remedy:
Pre-select Parameter Mode and clear the error message. Check and
correct all parameters. When exiting Parameter Mode, the checksums
are recalculated.