ECODRIVE03-FL*-04VRS Parameters 9-63
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
CM06 Moment of Inertia of the Rotor
0.00003
[Kgm
2
]
This parameter indicates the moment of inertia of the rotor without load.
For motors with feedback memory (e.g. MKD), it is saved in the feedback
memory.
Input min.: 0.00001
Input max.: 1.00000
CM07 Holding Brake Type
0 0
0 = self-holding brake
0V at the brake, brake applied
1 = self-releasing brake
24V at the brake, brake applied
0 = servo brake
after maximum braking time, the brake is
activated.
1 = Main spindle brake
Brake is applied only at < 10 RPM
If a holding brake is used, this parameter specifies whether it is a self-
holding or self-releasing brake. If an MHD or MKD motor is used, the
holding brake, if there is one, is a self-holding one. Bit 0 is automatically
set to 0. When other motor types are used, this bit must be input at initial
startup.
CM08 Holding Brake Current
000.000
[A]
This parameter indicates how much current is drawn by the holding brake
in the in-circuit motor.
Input min.: 0
Input max.: 500.000