ECODRIVE03-FL*-04VRS EMD Module (EcoX-Bus) 15-23
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
15.8 Replacement of a Unit
CAUTION
Damage by live parts!
⇒ Turn off the power to the input/output module before
installing or removing it, so it is not damaged.
Following is a short list of items that must be considered when a unit is
replaced.
First, please note that the replacement of a unit in a drive control
system – consisting of a drive controller and an input/output module –
always also affects the unit that is not replaced.
The electronic module is plugged into the base module. The
Removal/Installation has already been described. The wiring of the
input/output module is not affected by replacing the electronic module.
For (re-)startup instructions for the electronic module, please see the
corresponding section.
For (re-)startup of the base module, the same description is valid as for
the electronic module.
A physical connection to the drive controller exists via the EcoX interface.
It is also necessary to set the parameters for the drive controller, so it can
communicate with the input/output module. Setting the parameters is not
necessary if the programming module is transferred to the replacement
unit.
Replacement of the Electronic
Module
Replacement of the Base Module
Replacement of the Drive
Controller