9-20 Parameters ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
AA06 Open Feed Roll II
This function is only valid in conjunction with Parameter AA05.
M2.02.1 M2.02.2
Input Bit : Open Feed Roll in
Manual Mode
00.00.0 = no opening possible in Manual Mode
M0 M5 ; M8 ; I0 I4 ; Q0 Q3
Input Bit : Enable Function (only in Automatic
Mode)
00.00.0 = No separate enable possible
M0 M5 ; M8 ; I0 I4 ; Q0 Q3
Open Feed Roll in Manual Mode
If the input for opening the feed rolls is high, the output for opening the
feed rolls is set (independently of the enable bit). Jogging is always
possible.
Enable Function
This function can also be enabled from the NC Program, Logic Task or
from an external input. Removing the enable signal while the function is
active has no effect on the output.
In Manual Mode, this function is always enabled.
Open Feed Roll
Input Bit AA05
Open Feed Roll
Output Bit AA05
Close Feed Roll
Input Bit AA05
Measuring Wheel Active
System Marker M1.03.2
Feed Roll Open
Wl_Out_AE.WMF
Fig. 9-8: Open Feed Roll with Acknowledgement Signal
Open Feed Roll
Input Bit AA05
Open Feed Roll
Output Bit AA05
Close Feed Roll
Time Acknowledgement AA05
Measuring Wheel Active
Time
System Marker M1.03.2
Feed Roll Open
Wtime_Out_AE.WMF
Fig. 9-9: Open Feed Roll with Time Acknowledgement