ECODRIVE03-FL*-04VRS Interface 10-33
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Readout of Status Information
The following status messages can be queried via the serial data
interface:
Status 00 = Actual Position in IU
Status 01 = Transmission error, interface
Status 04 = Counter
Status 05 = Firmware version
Status 08 = Current instructions and return instruction
numbers of tasks 1 through 3
Status 09 = Measuring Wheel Mode: Actual Position,
Measuring Wheel and Actual Position of the
Motor Encoder
Status 10 = Position Lag in IU
Status 19 = Hardware and firmware version
Status 25 = Two-digit diagnostic code with text output
Status 48 = Actual Velocity in 1/min
Status 53 = Diagnostic / Error Message
Status 60 = Output of first erroneous instruction number
(Parameter, NC Task, Logic Task)
Status 61 = Output of a byte for the Markers / Inputs /
Outputs
Status 62 = Controller Type or Motor Type
Status 63 = Text output (TXT command)
Status 64 = Two-digit diagnostic code
Status 66 = Output of a word for the Markers / Inputs /
Outputs
Status 00
Actual Position in IU
The status query:
?sX__00_ CR LF
produces the message:
Xs00_evmmmmmm.mmm__+000000.000$hh CR LF
Meaning of the characters used:
e=`_´ stands for relative position (not homed)
`A´ stands for absolute position (axis homed)
v = Operational sign of the actual position
m = Actual position of Axis 1 in IU