10-32 Interface ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
It is not possible to transfer table values in Automatic Mode.
The cam must begin with the value $00000000 in Element 0000, and the
last value in Element 1023 must be $7FFFFFFF.
Format:
#sTnn_eeee_pppppppp$hh CR LF
Meaning of the characters used:
s = Station Number
n = Table Number (00 only)
e = Table Element No. (from 0000 to 1023)
p = Standardized Positions [Hexadecimal Value]
(standardized to 2^31)
Note: Only table values <=$7FFFFFFF may be transferred.