ECODRIVE03-FL*-04VRS Interface 10-17
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Communications via RS485 Interface
Features
Communication via the RS485 interface makes it possible to implement a
serial bus with the following data:
Up to 8 drives can be connected to one bus master.
Transmission rates of: 2400 baud ASCII
4800 baud ASCII
9600 baud ASCII / SIS
19200 baud ASCII / SIS
Maximum transmission path: 500m
Half duplex mode over a 2-wire line
8-bit ASCII protocol or 8-bit SIS protocol
Parity bit: none, even, odd
one stop bit
Fs0005d1_AE.WMF
Fig. 10-15 Data Exchange of Drive Groups from an Operator Console
Transmission Protocols
When the 24V supply voltage is switched on, the data set in Parameters
B001, B002, B009 and B010 are used as the communications
parameters. If these settings do not correspond to the data in the
programming unit, the S1 button on the programming module can be
used to set the default transmission parameters. See also: "Initial Startup"
Chapter, S1 Button.