ECODRIVE03-FL*-04VRS Interface 10-11
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
M0.01
All bits in this byte are reserved.
M0.02
These marker flags are only valid if the function is enabled in the
designated parameter.
Status of the Function Inputs
Bit Function Source
0 Interrupt Parameter A116
1 Feed Angle Monitoring Parameter A116
2 Manual Vector Parameter AA01
3 Interrupt vector Parameter AA02
4 Reserved (Free) Restart
5 Reserved (Free) elektrisches Lüften
6 Reserved (Free) Motorbremse lüften
7 Measuring Wheel Control enabled Parameter AA07
Fig. 10-8: Marker Flags - Programmable System Inputs
Note: If the functions for bits 0 and 1 are not set in the parameters,
these bits are initialized by setting them to ’1.’
M0.03
All bits in this byte are reserved.
M0.04
All bits in this byte are reserved.
M0.05
All bits in this byte are reserved.
Here, the conditions are mirrored.
These marker flags are read-only using the Logic Task and the NC Task.
M1.00
Bit Function Source
0 Manual Mode Status
1 Automatic Status
2 Fault Status
3 Run Status
4 Ready Status
5 Warning Status
6 Parameter Status
7 In Position (Switching Threshold) Status
Fig. 10-9: Marker Flags - System Outputs
System Marker Flags (Outputs)