ECODRIVE03-FL*-04VRS Interface 10-27
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
CM00 CM00_1_
CM01 CM01_040_
CM02 CM02_0100.0_0070.0_
CM03 CM03_10500.000_
CM04 CM04_0003_
CM05 CM05_000.20_
CM06 CM06_0.00003_
CM07 CM07_0_0_
CM08 CM08_010.000_
CM09 CM09_123_123_
CM01 CM10_000.00_
CM11 CM11_+0000.0000_
CM12 CM12_00000_
N100 N100_0_360.00_
N101 N101_Q0.00.6_010_020_
through
...
N108 N108_Q0.00.7_010_020_
N109 N109_3000_04_003_005_
N110 Reserved (Free)
N111 N111_1_02_03_000_
N119 Reserved (Free)
N120 Reserved (Free)
N121 N121_2_180_270_
through
...
N131 N131_2_180_270_
Examples:
Query Response
?5K_B006_$hh CR LF K5B006_S_0_0001_$05 CR LF
?5K_A101_$hh CR LF K5A101_1234.5678_$B8 CR LF
Examples: Write
#5K_A103_+123456.789_$11 CR LF
#5K_CR00_655.35_$F1 CR LF
If no checksum validation function has been programmed prior to entering
Parameter Mode, this function remains disabled, even though Parameter
B002 has been overwritten, until Parameter Mode is exited.