14-4 Display ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Key Combinations with SHIFT
Symbol Definition
SHIFT+F6 Calls the BTV Parameter Menu. For details, see "BTV
Parameters“
SHFIT+ESC Causes a re-boot of the BTV04. This key combination is
equivalent to turning the BTV04's 24V power supply off and then
on again.
The following keys are active only when "Serial System Control"
(Parameter B010) is active.
PARA – The controller switches to Parameter Mode. Pressing the
key again closes Parameter Mode. The controller then has a status
of "Ready" or "Manual."
START – When the system is in "Automatic" Mode, pressing this
key starts the program. In Manual and Parameter Modes, this key
has no function.
AUTO – The system switches to "Automatic" Mode. Pressing the
key again cancels Automatic Mode.
STOP – Causes an immediate stop of the system The equipment
is stopped as soon as possible, without completing the current
movement. The system may only be restarted when the error
source has been eliminated.
JOG-/JOG+ - In Manual Mode, a movement in the positive or
negative direction takes place. Movement occurs by pressing the
keys and is stopped by releasing the keys.
Fig. 14-4: Key Labels