ECODRIVE03-FL*-04VRS General Instructions for Start-Up 4-19
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Select the Download Baud Rate
Depending on the length of the serial interface cable, there is a physical
limit to the maximum baud rate at which serial communications will
proceed without errors.
The factory recommends a maximum download baud rate of 19.2 kBaud.
The baud rate can be increased considerably in some applications,
however, which helps achieve a reduction in the time needed for a
firmware update.
The following baud rates can be implemented at the specified cable
lengths.
Cable Length / m Max. Baud Rate / kBaud
2 115.2
5 57.6
10 57.6
15 38.4
Fig. 4-9: Maximum Baud Rate Depending on Cable Length