ECODRIVE03-FL*-04VRS Writing the User Program 6-11
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
System Variable V107 "Slip in Measuring Wheel Mode":
The slip between the optional Encoder 2 and Motor Encoder [%] (only in
Measuring Wheel Mode) is issued.
[]
Constant Rate Feed WheelMeasuring
WheelMeasuring of Rev. 1after DifferenceEncoder
% =Slip
Fig. 6-3: Calculation of the Slip
System Variable V108 "Target Velocity [IU/s]":
Output of the target velocity, not averaged.
System Variable V113 Distance from home position to processing
location [IU]:
All movements of the active measurement wheel are counted.
(only for application "Flying Cutoff)