OPERATOR’S MANUAL
CMA-9000 FLIGHT MANAGEMENT SYSTEM
DATA ENTRY
ADVISORY
MESSAGE
DESCRIPTION ACTION
!INVALID APPROACH
The selected approach is invalid or
corrupted.
If possible, select an alternate approach.
!INVALID APPR TRANS
The selected approach transition is invalid or
corrupted.
If possible, select an alternate approach or
approach transition.
!INVALID DATABASE
Attempt to activate an invalid database. Check database.
!INVALID DELETE
Attempt to DELETE an undeletable field. Select correct field for deletion or overwrite
the field data.
!INVALID ENTRY
Attempt to enter incorrect data to the
selected field.
Enter correct data for the desired field.
!INVALID FORMAT
Attempt to enter data having an incorrect
format for the selected field.
Enter correct data for the desired field.
!INVALID FREQUENCY
Entered frequency does not fall within the
valid range.
Re-enter valid frequency.
!INVALID IDENT
An invalid Ident was entered in the library. Enter a valid Ident (5 characters max.).
!INVALID
INTERSECTION
Place/Bearing-Place/Bearing inputs do not
intersect to form a valid waypoint or the
entered downtrack intersection does not
exist.
Review data entry. Modify as necessary.
!INVALID LINE SELECT
Invalid line select key was pressed. Choose valid LSK when deleting RADIO
library element.
!INVALID PRESET
Invalid Preset was entered in the library. Enter a valid Preset (00 to 99).
!INVALID RUNWAY
Operator selected an invalid runway (error in
database).
Select a runway in the database or enter
runway manually.
!INVALID SID
Operator selected an invalid SID (error in
database).
If possible, select alternate SID.
!INVALID SID TRANS
Operator selected an invalid SID TRANS
(error in database).
If possible, select alternate SID or SID
transition.
!INVALID STAR
Operator selected an invalid STAR (error in
database).
If possible, select alternate STAR or
manually enter STAR waypoints.
!INVALID STAR TRANS
Operator selected an invalid STAR TRANS
(error in database).
If possible, select alternate STAR or STAR
transition.
!INVALID X-TALK
CONFIG
Attempt to synchronize FMSs despite invalid
X-talk installation/ configuration.
Advise maintenance to verify dual FMS
system interconnects.
!LIBRARY IS LOCKED
Library is locked. Unlock the library before saving the Preset
frequencies.
!MACH CSTR IN CRZ
ONLY
Attempt to enter a Mach constraint on a
climb or descent waypoint, on an
incomplete profile, or inactive route.
For climb and descent speed constraints,
enter a speed in IAS. To enter a cruise
constant speed segment, ensure the profile
is completed and the active route is selected.
!MEMORY LOCKED
Attempt to modify protected memory. Unlock maintenance memory.
!MULTIPLE AWY
INTERSECTS
On RTE page, multiple common waypoints
are found between two successive airways.
Enter desired intersection waypoint in TO-
field of first airway.
!NO AIRWAY
INTERSECTION
No intersection is found when attempting to
link two airways on RTE page.
Enter proper waypoint in TO-field of first
airway.
!NO AWY WPTS TO
LOAD
On RTE page, the waypoint entered in the
TO-field of a pending airway is the same as
the starting waypoint of the airway (TO-field
of previous line).
Enter proper waypoint in TO-field of
pending airway.
Page E-20
August 17, 2010
DRAFT

Table of Contents