EasyManua.ls Logo

Intermec Antares 2420 - Page 202

Intermec Antares 2420
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Nugget
Co de 39
6-10
Problems While Configuring the Terminal (continued)
Problem Solution
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error.
SOM is set. You must also set
EOM.
Configuration was not updated.
You must configure a value for EOM before you can set SOM or
disable SOM. You need to change the value of SOM. Choose Serial
Port from the Communications Menu.
The configurable serial protocol (CSP) uses EOM to determine the
serial communications mode. When EOM is disabled, the terminal
communicates in Character mode. When EOM is enabled, the
terminal communicates in Frame mode. To use Frame mode, you need
to set EOM first. Next, configure Handshake, Configuration
Commands Via Serial Port, LRC, SOM, and then Poll.
For help, see “Using Serial Communications on the Terminals” in
Chapter 4.
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error.
SOM cannot equal EOM.
Configuration was not updated.
SOM cannot equal the same value that is set for EOM. You cannot set
SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll,
RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change
the value of SOM. Choose Serial Port from the Communications
Menu.
For help, see “Start of Message (SOM)” in Chapter 9.
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error.
EOM #1 cannot equal EOM #2.
Configuration was not updated.
EOM can be one or two ASCII characters, but you cannot set the first
and second character to the same character. Also, you cannot set EOM
to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES
(EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the
value of EOM #1 or #2. Choose Serial Port from the Communications
Menu.
For help, see “End of Message (EOM)” in Chapter 9.
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error. DLE, XON, XOFF are not
valid values for either SOM or
EOM.
Configuration was not updated.
You cannot set EOM or SOM to any of these values: AFF (ACK),
DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or
XON. You need to change the value of EOM or SOM. Choose Serial
Port from the Communications Menu.
For help, see “End of Message (EOM)” or “Start of Message (SOM)”
in Chapter 9.

Table of Contents

Other manuals for Intermec Antares 2420

Related product manuals