Table 37: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Designed to comply
with Zone 4
earthquake
requirements per
NEBS GR-63-CORE,
Issue 4.
•
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
•
Nonoperating storage
temperature in shipping
container: –40° F (–40° C)
through 158° F (70° C)
Normal operationensured in
the relative humidity range
5% through 90%,
noncondensing
•
Short-term operation
ensured in the relative
humidity range 5%
through 93%,
noncondensing
NOTE: As defined in
NEBS GR-63-CORE, Issue
4, short-term events can
be up to 96 hours in
duration but not more
than 15 days per year.
No performance
degradation to
6,562 feet
(2000 meters)
EX4600
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX6210
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8208
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8216
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operationensured in
the relative humidity range
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9204
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operationensured in
the relative humidity range
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9208
83Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Preparation Overview

Table of Contents

Other manuals for Juniper EX9208

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX9208 and is the answer not in the manual?

Juniper EX9208 Specifications

General IconGeneral
BrandJuniper
ModelEX9208
CategorySwitch
LanguageEnglish

Related product manuals