3 Language Dictionary
100 Keysight Models 6811C, 6812C, and 6813C Programming Guide
MEASure:VOLTage:ACDC?
FETCh:VOLTage:ACDC?
These queries return the AC+DC rms voltage being sourced at the output
terminals.
MEASure:VOLTage:HARMonic?
FETCh:VOLTage:HARMonic?
These queries return the rms amplitude of the Nth harmonic of output voltage.
The parameter is the desired harmonic number. Queries sent with a value of 0
return the DC component. A value of 1 returns the fundamental output frequency.
Harmonic orders can be queried up to the fundamental measurement bandwidth
of the measurement system, which is 12.6 kHz. Thus the maximum harmonic that
can be measured is dependent on the output frequency. Any harmonics that
represent frequencies greater than 12.6 kHz are returned as 0.
Query syntax MEASure:[SCALar]:VOLTage:ACDC?
FETCh:[SCALar]:VOLTage:ACDC?
Parameters None
Examples
MEAS:VOLT:ACDC? FETC:VOLT:ACDC?
Returned parameters <NR3>
Related commands MEAS:CURR:ACDC? MEAS:VOLT?
Query syntax MEASure:[SCALar]:VOLTage:HARMonic[:AMPLitude]? <NRf>
FETCh:[SCALar]:VOLTage:HARMonic[:AMPLitude]? <NRf>
Parameters 0 to 50
Examples
MEAS:VOLT:HARM? 3 FETC:VOLT:HARM? 1
Returned parameters <NR3>
Related commands MEAS:VOLT:HARM:PHAS? MEAS:VOLT:HARM:THD?

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals