3 Language Dictionary
146 Keysight Models 6811C, 6812C, and 6813C Programming Guide
LIST:VOLTage:OFFSet:SLEW
This command specifies the DC offset slew list points. The slew points are given in
the command parameters, which are separated by commas. The order in which
the points are entered determines the sequence in which they are output when a
list is triggered. Changing list data while a subsystem is in list mode generates an
implied ABORt.
LIST:VOLTage:OFFSet:SLEW:POINts?
This query returns the number of points specified in LIST:VOLTage:OFFSet:SLEW.
Note that it returns only the total number of points, not the point values.
Command syntax [SOURce:]LIST:VOLTage:OFFSet:SLEW <NRf+> | INF {, <NRf+> | INF}
Parameters 0 to 9.9E37 | MAXimum | MINimum | INFinity
Unit V (volts per second)
Examples
LIST:VOLT:OFFS:SLEW 10, 20, 1E2
Query syntax [SOURce:]LIST:VOLTage:OFFSet:SLEW?
Returned parameters <NR3>{, <NR3>}
Related commands LIST:VOLT:SLEW:POIN? LIST:COUN LIST:DWEL LIST:STEP
Query syntax [SOURce:]LIST:VOLTage:OFFSet:SLEW:POINts?
Returned parameters <NR1>
Examples
LIST:VOLT:OFFS:SLEW:POIN?
Related commands LIST:VOLT:OFFS:SLEW