Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 161
VOLTage:OFFSet:TRIGgered
This command selects the DC offset that the output waveform will be set to
during a triggered step or pulse transient.
The maximum peak voltage that the ac source can output is 425 V
peak
. This
includes any combination of voltage, voltage offset, and function shape values.
Therefore, the maximum value that can be programmed depends on the
peak-to-rms ratio of the selected waveform. For a sine wave, the maximum
voltage that can be programmed is 300 V
rms
.
VOLTage:OFFSet:SLEW
This command sets the slew rate for all programmed changes in DC output
voltage. A parameter of MAXimum or INFinity sets the slew to its maximum
possible rate. The SCPI representation for INFinity is 9.9E37.
The OUTPut:COUPling must be set to DC to get non-zero DC output.
Command syntax [SOURce:]VOLTage:OFFSet:TRIGgered <NRf+>
Parameters –425 to +425 | MAXimum | MINimum
Unit V (DC voltage)
*RST value 0
Examples
VOLT:OFFS:TRIG 50 VOLT:OFFS:TRIG INF
Query syntax [SOURce:]VOLTage:OFFSet:TRIGgered?
Returned parameters <NR3>
Related commands VOLT:OFFS:MODE OUTP:COUP
Command syntax [SOURce:]VOLTage:OFFSet:SLEW[:IMMediate] <NRf+> | INFinity
Parameters 0 to 9.9E37 | MAXimum | MINimum | INFinity
Unit V (volts per second)
*RST value INFinity
Examples
VOLT:OFFS:SLEW 50 VOLT:OFFS:SLEW MAX
Query syntax [SOURce:]VOLTage:OFFSet:SLEW[:IMMediate]?
Returned parameters <NR3>
Related commands VOLT:OFFS:MODE OUTP:COUP