2 Introduction to Programming
34 Keysight Models 6811C, 6812C, and 6813C Programming Guide
RS-232 troubleshooting
If you are having trouble communicating over the RS-232 interface, check the
following:
The computer and the ac source must be configured for the same baud rate,
parity, and number of data bits. Note that the ac source is configured for 1
start bit and 2 stop bits (these values are fixed).
The correct interface cables or adapters must be used, as described under
“RS-232 connector” in the User's Guide. Note that even if the cable has the
proper connectors for your system, the internal wiring may be incorrect.
The interface cable must be connected to the correct serial port on your
computer (COM1, COM2, etc.).
[Wait for response]
' END ' End of main program