Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 173
STATus:QUEStionable:CONDition?
This query returns the value of the Questionable Condition register. That is a
read-only register which holds the real-time (unlatched) questionable status of
the ac source.
STATus:QUEStionable:ENABle
This command sets or reads the value of the Questionable Enable register. This
register is a mask for enabling specific bits from the Questionable Event register to
set the questionable summary (QUES) bit of the Status Byte register. This bit
(Bit 3) is the logical OR of all the Questionable Event register bits that are enabled
by the Questionable Status Enable register.
Query syntax STATus:QUEStionable:CONDition?
Parameters None
Examples
STAT:QUES:COND?
Returned parameters <NR1> (register value)
Related commands STAT:OPER:COND?
Command syntax STATus:QUEStionable:ENABle <NRf+>
Parameters 0 to 32767 | MAXimum | MINimum
Default value 0
Examples
STAT:QUES:ENAB 32 STAT:QUES:ENAB 1
Query syntax STATus:QUEStionable:ENABle?
Returned parameters <NR1> (register value)
Related commands STAT:QUES?