EasyManua.ls Logo

Keysight Technologies 6811C

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Language Dictionary
104 Keysight Models 6811C, 6812C, and 6813C Programming Guide
OUTPut
This command enables or disables the ac source output. The state of a disabled
output is an output voltage amplitude set to 0 volts, with output relays opened.
The query form returns the output state.
For Keysight 6812C/6813C Option 026 only, this command controls the on/off
state of both the main and auxiliary outputs.
OUTPut:COUPling
This command enables AC or DC output coupling. When the output coupling is
set to AC, a DC leveling loop attempts to maintain zero average output voltage.
The loop has a corner frequency of about 2 Hz. It will not prevent short transient
waveforms that may have non-zero average voltage, but will cause a settling
transient to an average value of 0 volts.
The output coupling must be set to DC to obtain DC output with VOLTage:OFFSet,
or to generate output transients that have net DC components.
Command syntax OUTPut[:STATe] <bool>
Parameters 0 | 1 | OFF | ON
*RST value OFF
Examples
OUTP 1 OUTP:STAT ON
Query syntax OUTPut[:STATe]?
Returned parameters 0 | 1
Related commands *RCL *SAV
Command syntax OUTPut:COUPling <coupling>
Parameters AC | DC
*RST value AC
Examples
OUTP:COUP DC
Query syntax OUTPut:COUPling?
Returned parameters <CRD>
Related commands *RCL *SAV