156 Keysight Models 6811C, 6812C, and 6813C Programming Guide
VOLTage:TRIGgered
This command selects the AC rms amplitude that the output waveform will be set
to during a triggered step or pulse transient.
The maximum peak voltage that the ac source can output is 425 V
peak
. This
includes any combination of voltage, voltage offset, and function shape values.
Therefore, the maximum value that can be programmed depends on the
peak-to-rms ratio of the selected waveform. For a sine wave, the maximum
voltage that can be programmed is 300 V
rms
.
Command syntax [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <NRf+>
Parameters For sine waves: 0 to 300 | MAXimum | MINimum
Unit V (rms voltage)
*RST value 0
Examples
VOLT:TRIG 120 VOLT:LEV:TRIG 150
Query syntax [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]?
Returned parameters <NR3> (if the trigger level is not programmed, the immediate level is returned)
Related commands VOLT VOLT:MODE VOLT:OFFS FUNC:SHAP

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals