CURRent:PEAK:TRIGgered
This command determines how the peak current limit is controlled during a
triggered output transient. The choices are as follows:
Command syntax [SOURce:]CURRent:PEAK:TRIGgered <NRf+>
Parameters MINimum | MAXimum |
0 to 3.25 (6811C including all options)
0 to 6.50 (6812C including all options)
0 to 13.0 (6813C all options except Option 019)
0 to 16.0 (6813C Option 019)
Unit A (peak amperes)
*RST value 13 (6811C/6812C including all options)
26 (6813C all options except Option 019)
32 (6813C Option 019)
Examples
CURR:PEAK:TRIG 15
Query syntax [SOURce:]CURRent:PEAK:TRIGgered?
Returned parameters <NR3>
Related commands CURR:PEAK CURR:PEAK:MODE