EasyManua.ls Logo

Keysight Technologies 6811C

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 133
FUNCtion:CSINusoid
This command sets the clipping level when a clipped sine output waveform is
selected. The clipping characteristics can be specified in two ways:
The clipping level is expressed as a percentage of the peak amplitude at which
clipping occurs. The range is 0 to 100 percent. These are the default units
when the optional THD suffix is not sent.
The clipping level is expressed at the percentage of total harmonic distortion in
the output voltage. The range is 0 to 43 percent. The optional THD suffix is
sent to program in these units.
Command syntax [SOURce:]FUNCtion[:SHAPe]:CSINusoid <Nrf> [THD]
Parameters 0 to 100% | 0 to 43% THD
*RST value 100% | 0% THD (no clipping)
Examples
FUNC:CSIN 80 FUNC:CSIN 10 THD
Query syntax [SOURce:]FUNCtion[:SHAPe]:CSINusoid? [THD]
Returned parameters <NR3>
Related commands FUNC FUNC:MODE

Table of Contents

Other manuals for Keysight Technologies 6811C

Related product manuals