3 Language Dictionary
202 Keysight Models 6811C, 6812C, and 6813C Programming Guide
TRIGger:SEQuence2:SOURce
TRIGger:SYNChronize:SOURce
These commands select the synchronizing trigger source in generating a step,
pulse, or list output as follows:
IMMediate: Starts the transient output immediately, unless a delay time other
than 0 has been specified by TRIGger:DELay. In this case the transient output
starts after the expiration of the delay time.
PHASe: Starts the transient output at the reference phase set by
TRIG:SYNC:PHAS.
Command syntax TRIGger:SEQuence2:SOURce <CRD>
TRIGger:SYNChronize:SOURce <CRD>
Parameters IMMediate | PHASe
*RST value IMMediate
Examples
TRIG:SYNC:SOUR IMM TRIG:SEQ2:SOUR PHAS
Query syntax TRIGger:SEQuence2:SOURce?
TRIGger:SYNChronize:SOURce?
Returned parameters <CRD>
Related commands ABOR TRIG TRIG:DEL TRIG:SOUR TRIG:SYNC:PHAS
INIT INIT:CONT *TRG WAI