Keysight Models 6811C, 6812C, and 6813C Programming Guide 63
CALibrate:PHASe:AUXiliary
CALibration:PHASe:AUXiliary
Keysight 6812C/6813C Option 026 only.
Initiates calibration of the auxiliary output phase.
CALibrate:PWM:FREQuency
CALibration:PWM:FREQuency
This command is only used during manufacture or repair. It trims the switching
frequency of the power output stages. The numbers from 0 to 7 are internally
mapped to 8 discrete frequencies.
Command syntax CALibrate:PHASe:AUXiliary <NRf>
CALibration:PHASe:AUXliary <NRf>
Parameters 0 through 7
Examples
CAL:PHAS:AUX 1
Command syntax CALibrate:PWM:FREQuency <NRf>
CALibration:PWM:FREQuency <NRf>
Parameters 0 through 7
Examples
CAL:PWM:FREQ 1
Query syntax CALibrate:PWM:FREQuency?
CALibration:PWM:FREQuency?
Returned parameters <NR1>
Related commands CAL:PWM:RAMP