3 Language Dictionary
204 Keysight Models 6811C, 6812C, and 6813C Programming Guide
TRIGger:SEQuence3:SOURce
TRIGger:ACQuire:SOURce
These commands select the trigger source for a triggered measurement sequence
as follows:
– BUS: GPIB device, *TRG, or <GET> (Group Execute Trigger)
– EXTernal: AC source's backplane Trigger In BNC
– TTLTrg: The signal driving the Trigger Out BNC
Command syntax TRIGger:SEQuence3:SOURce <CRD>
TRIGger:ACQuire:SOURce <CRD>
Parameters BUS | EXTernal | TTLTrg
*RST value BUS
Examples
TRIG:ACQ:SOUR BUS TRIG:SEQ3:SOUR EXT
Query syntax TRIGger:SEQuence3:SOURce?
TRIGger:ACQuire:SOURce?
Returned parameters <CRD>
Related commands ABOR TRIG TRIG:DEL TRIG:SYNC TRIG:SYNC:PHAS
INIT INIT:CONT *TRG WAI