PHASe:TRIGgered
This command sets the output phase when a triggered step or pulse transient
occurs. The phase of the output voltage waveform is expressed relative to an
internal reference. The phase angle is programmed in degrees. Positive phase
angles are used to program the leading phase, and negative phase angles are
used to program the lagging phase.
Command syntax [SOURce:]PHASe:TRIGgered <NRf+>
Parameters –360 through +360 (degrees) | MAXimum | MINimum
*RST value 0
Examples
PHAS:TRIG 90 PHAS:TRIG MAX
Query syntax [SOURce:]PHASe:TRIGgered?
Returned parameters <NR3>
Related commands PHAS:MODE PHAS