Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 153
PULSe:PERiod
This command sets the period of a triggered output transient. The command
parameters are model-dependent.
PULSe:WIDTh
This command sets the width of a transient output pulse. The command
parameters are model-dependent.
Command syntax [SOURce:]PULSe:PERiod <NRf+>
Parameters 0 to 4.30349E5 | MINimum | MAXimum
Unit s (seconds)
*RST value 0.03333
Examples
PULS:PER 0.001 PULS:PER MIN
Query syntax [SOURce:]PULSe:PERiod?
Returned parameters <NR3>
Related commands PULS:COUN PULS:DCYC PULS:HOLD PULS:WIDT
Command syntax [SOURce:]PULSe:WIDTh <NRf+>
Parameters 0 to 4.30349E5 | MINimum | MAXimum
Unit s (seconds)
*RST value 0.01667 (equals the period of a single 60 Hz cycle)
Examples
PULS:WIDT 0.001 PULS:WIDT MIN
Query syntax [SOURce:]PULSe:WIDTh?
Returned parameters <NR3>
Related commands PULS:COUN PULS:DCYC PULS:PER PULS:HOLD