EasyManuals Logo

Keysight Technologies 6811C Programming Guide

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
3 Language Dictionary
98 Keysight Models 6811C, 6812C, and 6813C Programming Guide
Measurement Subsystem (Voltage) Commands
This subsystem programs the voltage measurement capability of the ac source.
Two measurement commands are available: MEASure and FETCh. MEASure
triggers the acquisition of new measurement data before returning a reading.
FETCh returns a reading computed from previously acquired data.
For Keysight 6811C/6812C/6813C Option 020 only, all standard ac source
MEASure or FETCh functions are available for the Main Output of the ac source as
well as the Power Analyzer input. The SENSe:NSELect command selects the
measurement source that will return data.
Subsystem syntax
MEASure | FETCh
[:SCALar]
:VOLTage
[:DC]? Returns DC component of the voltage
:AC? Returns AC rms voltage
:ACDC? Returns AC+DC rms voltage
:HARMonic
[:AMPLitude]? <n> Returns amplitude of the Nth harmonic of voltage
:PHASe? <n> Returns phase of the Nth harmonic of voltage
:THD? Returns % of total harmonic distortion of voltage
:RANKed? <n> Returns the voltage value for the percentile rank given

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals