3 Language Dictionary
150 Keysight Models 6811C, 6812C, and 6813C Programming Guide
Source Subsystem (Pulse) Commands
This subsystem controls the generation of output pulses. The PULSe:DCYCle,
PULSe:HOLD, PULSe:PERiod, and PULSe:WIDTh commands are coupled, which
means that the values programmed by any one of these commands can be
affected by the settings of the others. Refer to the tables under “PULSe:HOLD” on
page 151 for an explanation of how these commands affect each other.
Subsystem syntax
PULSe:COUNt
This command sets the number of pulses that are output when a triggered output
transient occurs. The command accepts parameters in the range 1 through
9.9E37. If INFinity or MAXimum is sent, the output pulse repeats indefinitely.
[SOURce:]
PULSe
:COUNt <n> | INFinity Selects transient pulse count
:DCYCle <n> Selects pulse duty cycle
:HOLD <parameter> Selects parameter that is held constant (WIDTh | DCYCle)
:PERiod <n> Selects pulse period when the count is greater than 1
:WIDTh <n> Selects width of the pulses
Command syntax [SOURce:]PULSe:COUNt <Nrf+> | INFinity
Parameters 1 to 9.9E37 | MINimum | MAXimum | INFinity
*RST value 1
Examples
PULS:COUN 3 PULS:COUN MIN PULS:COUN INF
Query syntax [SOURce:]PULSe:COUNt?
Returned parameters <NR3>
Related commands PULS:DCYC PULS:HOLD PULS:PER PULS:WIDT

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals