OUTPut:IMPedance:REACtive
This command sets the real part of the output impedance of the ac source.
OUTPut:IMPedance:STATe must be enabled for the programmed impedance to
affect the output.
OUTPut:PON:STATe
This command selects the power-on state of the ac source. The following states
can be selected:
– RST: Sets the power-on state to *RST. Refer to the *RST command as
described later in this chapter for more information.
– RCL0: Sets the power-on state to *RCL 0. Refer to the *RCL command as
described later in this chapter for more information.
Command syntax OUTPut:IMPedance:REACtive <NRf>
Parameters 0.00002 to 0.001
Unit H (henrys)
*RST value 0.00005
Examples
OUTP:IMP:REAC 100E-6
Query syntax OUTPut:IMPedance:REAC?
Returned parameters <NR3>
Related commands OUTP:IMP OUTP:IMP:REAL
Command syntax OUTPut:PON:STATe <state>
Parameters RST | RCL0
Examples
OUTP:PON:STAT RST
Query syntax OUTPut:PON:STATe?
Returned parameters <CRD>
Related commands *RST *RCL

Table of Contents

Other manuals for Keysight Technologies 6811C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies 6811C and is the answer not in the manual?

Keysight Technologies 6811C Specifications

General IconGeneral
BrandKeysight Technologies
Model6811C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals