EasyManua.ls Logo

Keysight Technologies 6811C

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 107
OUTPut:IMPedance:REACtive
This command sets the real part of the output impedance of the ac source.
OUTPut:IMPedance:STATe must be enabled for the programmed impedance to
affect the output.
OUTPut:PON:STATe
This command selects the power-on state of the ac source. The following states
can be selected:
RST: Sets the power-on state to *RST. Refer to the *RST command as
described later in this chapter for more information.
RCL0: Sets the power-on state to *RCL 0. Refer to the *RCL command as
described later in this chapter for more information.
Command syntax OUTPut:IMPedance:REACtive <NRf>
Parameters 0.00002 to 0.001
Unit H (henrys)
*RST value 0.00005
Examples
OUTP:IMP:REAC 100E-6
Query syntax OUTPut:IMPedance:REAC?
Returned parameters <NR3>
Related commands OUTP:IMP OUTP:IMP:REAL
Command syntax OUTPut:PON:STATe <state>
Parameters RST | RCL0
Examples
OUTP:PON:STAT RST
Query syntax OUTPut:PON:STATe?
Returned parameters <CRD>
Related commands *RST *RCL

Table of Contents

Other manuals for Keysight Technologies 6811C

Related product manuals