126 Keysight Models 6811C, 6812C, and 6813C Programming Guide
FREQuency:TRIGgered
This command programs the frequency that the output will be set to during a
triggered step or pulse transient.
Command syntax [SOURce:]FREQuency:TRIGgered <NRf+>
Parameters MINimum | MAXimum |
0.001 to 1000 (6811C/6812C/6813C except Option 019)
0.001 to 100 (6813C Option 019)
Unit Hz (hertz)
*RST value 60
Examples
FREQ:TRIG 50
Query syntax [SOURce:]FREQuency:TRIGgered?
Returned parameters <NR3>
Related commands FREQ FREQ:MODE