3 Language Dictionary
70 Keysight Models 6811C, 6812C, and 6813C Programming Guide
CALibrate:VOLTage:AUXiliary
CALibration:VOLTage:AUXiliary
Keysight 6812C/6813C Option 026 only.
Initiates calibration of the auxiliary output voltage.
CALibrate:VOLTage:DC
CALibration:VOLTage:DC
This command can only be used in calibration mode. It initiates the calibration of
the DC voltage programming circuits.
CALibrate:VOLTage:EXTernal
CALibration:VOLTage:EXTernal
Keysight 6811C/6812C/6813C Option 020 only.
Initiates calibration of the external voltage measurement.
Command syntax CALibrate:VOLTage:AUXiliary[:AC]
CALibration:VOLTage:AUXiliary[:AC]
Parameters None
Examples
CAL:VOLT:AUX
Command syntax CALibrate:VOLTage:DC
CALibration:VOLTage:DC
Parameters None
Examples
CAL:VOLT:DC
Related commands CAL:SAVE CAL:STAT
Command syntax CALibrate:VOLTage:EXTernal
CALibration:VOLTage:EXTernal
Parameters None
Examples
CAL:VOLT:EXT