Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 117
Source Subsystem (Current) Commands
This subsystem programs the output current of the ac source.
Subsystem syntax
[SOURce:]
:CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] <n> Sets the rms current limit
:PEAK
[:IMMediate] <n> Sets the peak current limit
:MODE <mode> Sets peak current limit mode (FIX | STEP | PULS | LIST)
:TRIGgered <n>
:PROTection Sets the transient level for peak current limit
:STATe <bool> Enable/Disable rms current limit protection