EasyManua.ls Logo

Keysight Technologies 6811C

Keysight Technologies 6811C
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Language Dictionary 3
Keysight Models 6811C, 6812C, and 6813C Programming Guide 209
*IDN?
This query requests the ac source to identify itself. It returns the data in four fields
separated by commas.
*LRN?
This query returns a binary string of all of the saved EEPROM values required to
set the instrument into its current state. It is not compatible with the Telnet
interface. The returned string includes “SYSTEM:SET” command header that can
be used directly provided the receiver can accept binary data.
Query syntax *IDN?
Parameters None
Returned parameters <AARD> Field Information
Keysight Technologies Manufacturer
xxxxC Model number
MYxxxxxxxx Serial number or 0
x.x.x-x.x.x-x.x.x Firmware revision
Examples
Keysight Technologies,6813C,MY00000000,1.0.0-1.0.0-1.0.0
Query syntax *LRN?
Parameters None
Returned parameters <binary_block>
Related commands SYST:SET

Table of Contents

Other manuals for Keysight Technologies 6811C

Related product manuals