List transients
List mode lets you generate complex sequences of output changes with rapid,
precise timing, which may be synchronized with internal or external signals. Each
function that can participate in output transients can also have an associated list
of values that specify its output at each list point.
You can program up to 100 settings (or points) in the list, the time interval (dwell)
that each setting is maintained, the number of times that the list will be executed,
and how the settings change in response to triggers. All list point data is stored in
non-volatile memory. This means that the programmed data for any list function
will be retained when the ac source is turned off.
Lists are paced by a separate list of dwell times which define the duration of each
output setting. Therefore, each of the up to 100 list points has an associated dwell
time, which specifies the time (in seconds) that the output remain at that setting
before moving on to the next setting.
The following procedure shows how to generate a simple list of voltage and
frequency changes.
Step 1 Set the mode of each function that will participate in the output
sequence to LIST. For example:
VOLTage:MODE LIST
FREQuency:MODE LIST